The Occupational Safety and Health (Noise Exposure) Regulations 2019 are Malaysia’s rules on noise at work, enforced by the Department of Occupational Safety and Health, DOSH (JKKP). They came into operation on 1 June 2019 and apply to every employer, not only to factories.
Many summaries reduce the Regulations to a single noise limit. The text actually uses two numbers. Above 82 dB(A), noise counts as excessive and calls for a registered assessor. Above 85 dB(A), the exposure limit is crossed and the noise has to come down.
In this guide, we sort each duty by the number that triggers it and by its deadline, with the regulation it comes from:
The Regulations were published in the Federal Government Gazette as P.U.(A) 60 on 1 March 2019, under section 66 of the Occupational Safety and Health Act 1994 [Act 514]. The text runs to 11 regulations, and each duty carries its own penalty clause. The first duty is addressed to “every employer,” with no list of sectors.
Alongside them, DOSH issued the Industry Code of Practice for Occupational Noise Exposure Management and Hearing Conservation 2019, known as the ICOP. DOSH’s FAQ states that the code took effect at the same time as the Regulations.
The Regulations define two sets of thresholds. Each set is crossed as soon as any one of its four measures is exceeded.
| Excessive noise (Reg. 2) | Exposure limit (Reg. 6(1)) | |
|---|---|---|
| Daily noise exposure level | Above 82 dB(A) | Above 85 dB(A) |
| Daily personal noise dose | Above 50% | Above 100% |
| Maximum level, at any time | Above 115 dB(A) | Above 115 dB(A) |
| Peak sound pressure level | Above 140 dB(C) | Above 140 dB(C) |
Crossing the first column calls in a registered assessor and yearly training for exposed workers. Crossing the second calls for noise reduction, hearing protection zones and annual audiometric tests.
The maximum and peak values are the same in both columns. What separates them is the daily level and the daily dose. The term “action level” appears in some guides, but the Regulations never use it.
A slip that shows up in published advice is linking hearing tests to the first column. Regulation 9(1) ties annual audiometric testing to the exposure limit, as shown in the noise risk assessment report.
Every employer must identify whether employees may be exposed to excessive noise, in the manner the Director General of DOSH determines. In practice, DOSH’s FAQ says the employer completes the code’s Noise Hazard Identification Checklist for each work area, according to its activity or process.
The identification is not a one-off. Regulation 3(2) requires it again after any change in machinery, equipment, process, work, control measures or operation that may raise exposure. It must also be repeated within one year of the previous one, or when the Director General directs it. DOSH adds that no legal provision lets an employer stop, even once a site finds no noise risk.
If the identification shows that employees may be exposed to excessive noise, the employer must appoint a noise risk assessor to carry out a noise risk assessment (NRA). Under Regulation 4(2), the assessor must be registered with the Director General and hold a valid certificate from the Director General for this work.
Before you appoint anyone, check the name. DOSH publishes its directory of registered assessors on its website. The assessor must measure with equipment that meets the International Electrotechnical Commission standard, and DOSH’s FAQ gives each instrument a calibration validity of 12 months.
Chemicals follow the same principle. A chemical health risk assessment must also be carried out by an assessor registered with DOSH, as our guide to CHRA DOSH requirements explains.
The assessor has one month from completing the assessment to submit the report, with its findings and recommendations (Regulation 4(4)). From the day you receive it, two deadlines run:
The assessment itself is reviewed no more than five years after the previous one, or sooner if the Director General directs it (Regulation 4(8)). This review cycle is separate from the yearly identification in Step 1.
Where the report shows exposure above the limit, the employer must reduce the noise. First it assesses whether engineering or administrative control is practicable, and writes that up for DOSH to request (Regulation 6(3) and 6(5)).
Then Regulation 6(4) fixes the order: engineering control first, then engineering and administrative control combined, then administrative control alone. Personal hearing protectors come in only when none of these is practicable.
A hearing protector must be suitable, properly maintained and available at all times. Worn properly, it must bring exposure below the limit, and it must be approved by the Director General (Regulation 7).
Any area where exposure exceeds the limit must be marked with the words “HEARING PROTECTION ZONE” and, where practicable, demarcated with a warning sign (Regulation 8). DOSH’s FAQ adds that a sign alone is not enough, and that zones come from noise mapping. Anyone inside the zone, employee or not, must wear the protector the employer provides.
Annual audiometric tests apply to every employee whose exposure exceeds the limit, according to the noise risk assessment report. The employer appoints an audiometric testing centre approved by the Director General. An occupational health doctor registered with DOSH interprets each audiogram.
The first test, which DOSH’s FAQ calls the baseline, must take place within three months of the employee starting work in an area above the limit. Before every test, the worker needs at least 14 hours of quiet without a hearing protector. The Regulations define quiet as no exposure above 80 dB(A).
The centre sends its report within 30 days of the test, and the employer informs the employee within 21 days of receiving it. A temporary standard threshold shift calls for a retest within three months. If the doctor finds occupational noise-induced hearing loss, the employer notifies the nearest DOSH office within seven days, provides a hearing protector and trains the employee to use it.
Employees exposed to excessive noise, according to the report, must learn how noise affects hearing and why they need audiometric testing. They are also trained to use hearing protectors properly, at least once a year. DOSH’s FAQ says any party can deliver this training, and lists what it covers, from the Regulations to the site’s noise control plans.
Two records have long lives under Regulation 11. The noise risk assessment report is kept for at least 30 years. Each employee’s audiometric test reports are kept for as long as they work for you, and for five years after they leave. If the business changes hands, the records go to the new owner, and DOSH gets three months’ written notice before any is disposed of.
Both are on DOSH’s website, dosh.gov.my. The official PDF of gazette P.U.(A) 60 is bilingual, with the Malay text first and the English text after it. The code, by contrast, is linked in Malay only.
In 2022, the Malaysian Industrial Hygiene Association asked its members for feedback on a draft DOSH guideline on occupational noise control. We have not seen a final version, so this guide follows the 2019 texts as checked in October 2026.
Noise risk assessment is listed among our assessment services. Whoever carries out the noise risk assessment must be registered with the Director General, as Regulation 4(2) requires, so check the name in DOSH’s directory first. If your organization is not sure which of these duties apply to its site, we can look at where you stand and what should come next.
Connect with us today to talk it through. Call or WhatsApp +6010 208 0698, email in**@*********************om.my, or get a free consultation.
No. The duty to identify excessive noise is addressed to every employer. In its FAQ, DOSH also answers that a die-casting company operating only twice a month still needs a noise risk assessment, carried out while the work is running.
No. DOSH’s FAQ says measuring instruments are not required for the identification, which is done with the code’s checklist. Readings from smartphone apps can still serve as an initial indicator, for example to judge whether planned control measures are working.
Only after passing the transition course. DOSH’s FAQ states that the assessment must be carried out by a noise risk assessor registered with the Department. Only those who attended and passed the Transition for Noise Competent Person Course may carry out noise risk assessments.
Yes, within the deadline set by Regulation 4(7). DOSH’s FAQ adds one step first: before installing engineering controls, the employer assesses their type, specifications, costs and other relevant aspects to confirm they are practicable.
The employer pays. Regulation 10 requires the tests to be carried out at no cost to the employee. DOSH’s FAQ says they continue for as long as the employee works in areas that exceed the exposure limit.
Each duty in the Regulations ends with the same penalty clause. On conviction, the offender is liable to a fine of up to RM10,000, imprisonment of up to one year, or both. Under Regulation 4, the clause applies to “any person,” which also covers the assessor’s own duties.